Emergency power systems is not alone. Fire lighting is not a single step, but a system of interdependence and mutual help, so the wiring requirements for each module are also strict.
1. The heat resistant wire is used in Emergency power systems, and the steel pipe can also be used as a non - delayed ignition wire with a heat - resistant temperature of more than 105. If BV-105 uses insulation and protective cover as non - delayed material type cable, it can be protected without metal tube, but it should be laid in the cable well. When a shaft is shared by a strong and weak electric cable, it should be separated on both sides of the shaft. When crossing pipe wear protection. The isolation plate shaft every layer to set as flame retardant materials, and will be on the next hole blocked.
2. Non - delayed material should be used when non - metal pipes are used. It is put in the wall structure which can not be burned.
3. Lines of different Emergency power systems, different voltages and different types of current can not be worn within the same channel or in the same slot in the same tube or the same line slot. The terminal boards in the distribution box should be separated separately from the lines of different voltage and different current categories, and should be clearly marked in the distribution box. The lines in different fire zones can not be shared.
4. The total sectional area of insulated conductors or cables in the distribution box for pipe piercing must not be more than 40% of the net sectional area of the tube holes.
5. The total cross section of a wire or cable laid in a closed or line groove should not be larger than the net section area of the line slot
6. The anticorrosive steel core aluminum strand should be selected in the coastal salt fog area.
What are the requirements for the wiring when the EPS emergency power supply is used?
Promulgator : TAIXIDate : 2018-01-13Views : 1575
READ MORE
- The main principles of low voltage circuit breaker selection
- Reliability index of miniature circuit breaker
- It is not a good idea to use a circuit breaker directly in the motor circuit
- Meaning of parameters on the nameplate of the circuit breaker
- Structure and Operation of LV Circuit Breakers
- How to make a choice between Low Voltage Circuit Breaker and Fuse
- The connection modes of LV circuit breakers
- Working Principle and Internal Structure Diagram of AC Contactor
- Working Principle, Function, Model Selection and Notice of Low Voltage Circuit Breaker
- Daily maintenance of miniature circuit breakers
- Introduction of Auto Reclosing Circuit Breaker
- How to detect and identify fault arc in AFCI (Arc Fault Circuit Breaker)?
- Working Principle of Low Voltage Circuit Breaker
- Rules for Safe Use of Circuit Breakers
- New technology - AFCI (Arc Fault circuit breaker), has changed our choice