With the advance of the construction of smart grid, the charge control system of the electric energy meter is the foundation of large scale, and has been paid much attention by the national Power Grid Corp and the South Network Power Grid Corp. In order to further improve the reliability of the power meter's cost control system and ensure the safe and stable operation of intelligent management and intelligent service of the power system, the national Power Grid Corp and the southern Power Grid Corp set up the technical specification for the external circuit breaker of the electric energy meter, respectively. According to this specification, the future electric appliance specializes in the development of the 20 30 40 50 60 amp auto reset circuit breaker (hereinafter referred to as TXB8F-80).
The basic functions of TXB8F-80 (20 30 40 50 60 amp auto reset circuit breaker) are: reliable realization of arrears, automatic sluice, power failure, automatic closing and continuous electricity, and precise feedback of three state signals: closing, splitting and fault.
TXB8F-80 (20 30 40 50 60 amp auto reset circuit breaker) is designed by modularization, and its structure is a drive module and miniature circuit breakers. The drive module is only 18mm width, single phase plus N total width 54mm, three phase plus N total width 90mm. In the industry, it is the first to break through the unipolar 18mm width and the maximum rated working current of 100A. The small size ensures that the FAR6-W can be conveniently installed in the existing standard metering box.
TXB8F-80 miniature circuit breakers adopt the inner axis drive design, which ensures the synchronism, consistency and reliability of the circuit breaker. The drive module has the function of manual (semi automatic) and automatic selection, which can effectively prevent people from closing and stealing electricity.
TXB8F-80 miniature circuit breakers are suitable for the temperature range of -25-60 C, and the extreme environment can reach -40~70 C. Therefore, whether it is hot summer in the South or severe cold in winter in the north, FAR6-W can work reliably, and it also brings more choices to the installation location of the watch box, which can be installed indoors or installed outside the environment with large temperature difference.
TXB8F-80 electric energy meter external circuit breaker with "GB10963.1 for household and similar overcurrent protection circuit breaker" standard, in line with the national grid and China Southern Power Grid electric energy meter "external circuit breaker" technical specifications, in accordance with the CQC quality certification center "China meter external circuit breaker technology specification".
New technology for auto reset circuit breaker with electric energy meter
Promulgator : TAIXIDate : 2018-01-11Views : 1268
READ MORE
- The main principles of low voltage circuit breaker selection
- Reliability index of miniature circuit breaker
- It is not a good idea to use a circuit breaker directly in the motor circuit
- Meaning of parameters on the nameplate of the circuit breaker
- Structure and Operation of LV Circuit Breakers
- How to make a choice between Low Voltage Circuit Breaker and Fuse
- The connection modes of LV circuit breakers
- Working Principle and Internal Structure Diagram of AC Contactor
- Working Principle, Function, Model Selection and Notice of Low Voltage Circuit Breaker
- Daily maintenance of miniature circuit breakers
- Introduction of Auto Reclosing Circuit Breaker
- How to detect and identify fault arc in AFCI (Arc Fault Circuit Breaker)?
- Working Principle of Low Voltage Circuit Breaker
- Rules for Safe Use of Circuit Breakers
- New technology - AFCI (Arc Fault circuit breaker), has changed our choice