INTRODUCTION

SPDZ DC surge protection device is applicable to the low-voltage standard IEC EN 50539-11, and is used to protect the DC system and other equipment from overvoltage and instantaneous overvoltage damage. When DC system experiences surge overvoltage due to lightning strikes or other reasons, the protector immediately conducts within nanosecond time, introducing surge overvoltage to the ground, thereby protecting the electrical equipment on the point network. DC surge protection device is a plug-in structure that can be quickly replaced after a module failure; After the lightning protection module fails, the color of the indicator window changes from green to red, and an alarm signal is sent to the remote alarm device connected to the remote signal terminal of the product.

DC Surge protection device are widely used in photovoltaic combiner boxes, power inverters, DC distribution cabinets, etc. It has the advantages of high discharge current, fast response time, and low residual voltage. The maximum photovoltaic voltage reaches UC≤1500VDC.

FEATURES

1. Voltage types: DC 12V 24V 48V 110V 220V 500V 690V 800V 1000V 1200V 1500V
2. 8/20µs, T2 protection;
3. High discharge capacity, quick response, pluggable;
4. Double thermal disconnection devices, providing more reliable protection;
5. Visual window display, green means normal, Red means defect(need to change new module);
6. Remote terminal optional;

ELECTRICAL TECHNICAL PARAMETERS

Model SPDZ
Standard IEC EN50539-11; GB18802.11
Protection Grade T2, Class II
Max Continuous Working Voltage Uc DC 12V 24V 48V 70V 110V 220V 500V 690V 800V 1000V 1200V 1500V
Nominal Discharge Current In 8/20μs 20KA 30KA
Max Discharge Current In 8/20μs 40KA 60KA
Lightning Impulse Current 10/350μs 12.5KA
Voltage Protection Level Up 2.2KV-4KV
Number of Poles 2P / 3P
Response Time Ta ≤25ns
Connecting Cable ≥4mm², Ground Wire ≥6mm²
Method of Installation 35mm DIN Rail
Matched Fuse or Circuit Breaker ≥32A
Operating Temperature Range -40°C ~ +80°C
Housing Color Module/Base Black
Certificate CE, ISO9001-2015

WIRING DIAGRAM

MAIN STRUCTURE AND WORKING PRINCIPLE

In the photovoltaic power generation system, protective devices are connected between the positive and negative poles of the line and the ground. Under normal circumstances, the protective device is in a high resistance state. When a surge overvoltage occurs in the power grid due to lightning strikes or other reasons, the protective device will immediately conduct in nanoseconds, introducing the surge overvoltage to the ground, thereby protecting the electrical equipment on the power grid. When the surge voltage passes through the protective device and disappears, the protective device will change back to a high resistance state, This will not affect the normal operation of the power grid. The electrical schematic diagram of the surge protector is shown in the following figure.

CHIP

Max Continuous Working Voltage Uc Resistance Chip Size
1200VDC 1500VDC 34MM*34MM*10MM(encapsulation)
800VDC 1000VDC 34MM*34MM*8MM(encapsulation)
500VDC 690VDC 34MM*34MM*6MM(encapsulation)
110VDC 220VDC 34MM*34MM*4.4MM
12VDC 24VDC 48VDC 72VDC 34MM*34MM*3.3MM

OUTLINE AND INSTALLATION DIMENSIONS