China Circuit Breaker Manufacturers and Suppliers
  • Parameters

  • Details

  • Size&weight

  • Related

  • Video

  • Message

Product Overview

JBK Control Power Transformer are suitable for AC circuits with frequency of 50Hz/60Hz. They are used as control power, local lighting and indicator lights power of general electrical equipment in various types of machine tools and machinery equipment.
Control Power Transformer Meets the standard: Q/ZT 205. We are a professional Control Power Transformer manufacturer.

Model and meaning

Normal working conditions and installation conditions

The Control Power Transformer can work reliably under the following environmental conditions.
1. The altitude is not more than 2000m.
2. The upper limit of ambient air temperature is 40°C, and the lower limit is -5°C (when it needs to be used at higher than 40°C or below -5°C, it is necessary to specify the special order when ordering).
3. When the maximum temperature is 40°C, the relative humidity is not more than 50%, and high relative humidity can be allowed at a lower temperature, such as 90% at 20°C. Special measures should be taken for the occasional condensation due to temperature change.
4. Non-explosive medium, and there is no enough gas to corrode metal and destroy insulation, and conductive dust.
5. There are no significant shaking and shock vibrations.
6. The place that is not eroded by rain and snow.

Structure features

JBK Control Power Transformer is a updated product of bk control transformers. It is manufactured using imported materials and advanced technology. It has the features of reliable operation, low energy consumption, small size, safe wiring, and wide applicability.

Voltage type of JBK series Control Power Transformer

Model Primary voltage (V) Secondary voltage (V)
Control Lighting Indication signal
40VA 220V / 380V 110(127) (220) 24(36) (48) 6(12)
63VA
100VA
160VA
250VA
400VA
630VA
1000VA
1600VA
2000VA
2500VA

Outline and installation dimensions of JBK1 Control Power Transformer (Table 1).

Model Installation dimension (mm) Mounting hole (mm) Outline dimension (mm)
A C K J Bmax Dmax Emax
JBK1-40 80 63 5 9 97 88 108
JBK1-63 80 63 5 9 97 88 108
JBK1-100 80 70 5 9 97 94 108
JBK1-160 100 75 8 11 130 115 150
JBK1-250 100 80 8 11 130 138 150
JBK1-400 90 92 8 11 152 112 128
JBK1-630 130 90 8 14 152 108 150
JBK1-1000 125 123 8 14 173 186 174
JBK1-1600 160 120 10 20 265 195 270
JBK1-2000 160 130 10 20 265 205 280
Note: Outline and installation dimensions are for reference only. If the required dimensions needs to be changed, please specify when ordering.

Outline and installation dimensions of JBK2 Control Power Transformer (Table 2).

Model Installation dimension (mm) Mounting hole (mm) Outline dimension (mm)
A C K J Bmax Dmax Emax
JBK2-40 70 58 6 10 86 84 97
JBK2-63 70 58 6 10 86 84 97
JBK2-100 70 75 6 10 86 96 97
JBK2-160 100 75 8 11 130 115 150
JBK2-250 100 80 8 11 130 120 150
JBK2-400 100 95 8 11 130 135 150
Note: Outline and installation dimensions are for reference only. If the required dimensions needs to be changed, please specify when ordering.

Outline and installation dimensions of JBK3 Control Power Transformer

Model Installation dimension (mm) Mounting hole (mm) Outline dimension (mm)
A C K J Bmax Dmax Emax
JBK3-40 56 52 5 9 84 78 92
JBK3-63 56 52 5 9 84 78 92
JBK3-100 64 70 5 9 86 92 95
JBK3-160 84 72 6 11 98 97 105
JBK3-250 84 85 6 11 98 110 105
JBK3-300 90 88 6 11 122 109 125
JBK3-400 90 92 6 11 122 113 125
JBK3-500 90 105 6 11 122 126 125
JBK3-630 130 90 8 14 152 110 150
JBK3-800(vertical) 130 130 8 14 152 125 150
JBK3-800(horizontal) 160 142 7 14 230 170 156
JBK3-1000 160 142 7 14 230 170 156
JBK3-1600 180 155 7 14 258 185 168
JBK3-2000 210 175 7 14 285 210 175
Note: Outline and installation dimensions are for reference only. If the required dimensions needs to be changed, please specify when ordering.

Outline and installation dimensions of JBK4 Control Power Transformer

Model Installation dimension (mm) Mounting hole (mm) Outline dimension (mm)
A C K J Bmax Dmax Emax
JBK4-40 56 52 5 9 80 80 88
JBK4-63 56 52 5 9 80 80 88
JBK4-100 64 70 5 9 86 96 92
JBK4-160 84 72 6 11 98 98 110
JBK4-250 84 85 6 11 98 112 110
JBK4-300 90 88 6 11 122 108 128
JBK4-400 90 92 6 11 122 112 128
JBK4-500 90 105 6 11 122 125 128
JBK4-630 130 90 8 14 152 108 150
JBK4-800 (vertical) 130 105 8 14 152 123 150
JBK4-800 (horizontal) 160 142 7 14 230 170 156
Note: Outline and installation dimensions are for reference only. If the required dimensions needs to be changed, please specify when ordering.

Order Information

Product Name: Control Power Transformer
Product model: JBK3-250.
Output capacity: 250VA.
Frequency: 50Hz.
Rated input voltage: 380V.
Rated output voltage and output voltage capacity of each group: 110V (160VA) 24V (80VA) 6V (10VA).
If an isolation shield is needed between the input and output windings, please specify it when ordering.